Specifications: (see all)
Measured / controlled parameters
Chlorophyll fluorescence (Ft, Fm, Fm’, Fo, Fo’), PSII quantum yield (Y(II)), electron transport rate (ETR), quenching parameters (NPQ, qP), fluorescence induction and relaxation kinetics, sample temperature, light flux, actinic light intensity.
Measurement / analysis range
Actinic light intensity – 0 to 25 000 µmol photons m⁻² s⁻¹; measuring-light frequency – 10 to 200 000 Hz; pulse duration – 1 µs.
Measurement accuracy / precision
High sensitivity to modulated signals ± 1 % of scale; noise < 0.1 % of signal.
Analysis method / operating principle
Pulse-Amplitude-Modulation (PAM) method – modulated measuring light excites chlorophyll, fluorescence is detected with high selectivity even under strong ambient light.
Analysis / measurement time
Single measurement (SAT pulse) ≈ 1–2 s; fast kinetics with 10 µs resolution; long-term curves up to several hours.
Delivery Information DEPENDING ON THE SIZE AND QUANTITY OF THE PRODUCT Payment Pay quickly and conveniently

The PAM-2500 Portable Chlorophyll Fluorometer by Heinz Walz GmbH (Germany) continues the legacy of the PAM-2000/2100 series, integrating modern electronics and optical systems for high-precision chlorophyll fluorescence measurements and PSII performance evaluation.

The device utilizes pulse-modulated measuring light (1 µs pulses, 10–200 kHz) and actinic LED sources at 455 nm (blue), 630 nm (red), and 750 nm (far-red). It achieves exceptional signal sensitivity even under full sunlight, while allowing fluorescence analysis from basic to advanced kinetic levels — from Kautsky induction to fast fluorescence decay.

With the PamWin-3 software, users can perform automated measurement sequences via Script Files, manage saturation pulse analysis, and obtain reliable light and induction curves. The instrument supports both desktop and ultra-mobile touchscreen PCs (UMPCs) for convenient field operation.

Compact (23 × 10.5 × 10.5 cm) yet powerful, the PAM-2500 is perfectly suited for plant ecophysiology, stress screening, and fundamental research involving leaves, chloroplast suspensions, algae, and cyanobacteria.

Tags: Soil and plant analysis

Soil and plant analysis
Measured / controlled parameters
Chlorophyll fluorescence (Ft, Fm, Fm’, Fo, Fo’), PSII quantum yield (Y(II)), electron transport rate (ETR), quenching parameters (NPQ, qP), fluorescence induction and relaxation kinetics, sample temperature, light flux, actinic light intensity.
Measurement / analysis range
Actinic light intensity – 0 to 25 000 µmol photons m⁻² s⁻¹; measuring-light frequency – 10 to 200 000 Hz; pulse duration – 1 µs.
Measurement accuracy / precision
High sensitivity to modulated signals ± 1 % of scale; noise < 0.1 % of signal.
Analysis method / operating principle
Pulse-Amplitude-Modulation (PAM) method – modulated measuring light excites chlorophyll, fluorescence is detected with high selectivity even under strong ambient light.
Analysis / measurement time
Single measurement (SAT pulse) ≈ 1–2 s; fast kinetics with 10 µs resolution; long-term curves up to several hours.
Sample volume / sample volume range
Leaf area ≈ 1 cm² (with 2030-B clip) or cuvette volume 1–3 mL (KS-2500 model).
Applicable media
Plant leaves, chloroplast suspensions, algal and cyanobacterial cultures.
Sensor / electrode / probe / indicator type
High-sensitivity photodiode (fluorescence detector); multi-color LED sources (red 630 nm, blue 455 nm, far-red 750 nm).
Number of channels / measurement points
Single optical channel with connectable leaf or cuvette sensors.
Temperature compensation
Built-in temperature sensor with automatic temperature compensation for fluorescence response.
Number of calibration points / calibration method
Light-intensity and detector-gain calibration via PamWin-3; automatic self-calibration available.
Housing / chamber / tip material
Aluminum housing, fiber-optic probe with protective sheath, leaf clip of stainless steel and polymer.
Design and features
Compact unit (23 × 10.5 × 10.5 cm); all optical and electronic modules in one housing; detachable fiber optic cable.
Lighting / climate control system
Actinic LED sources (blue, red, far-red) and measuring light 630 nm pulsed up to 200 kHz.
Number of programmable cycles / automatic modes
Automated protocols via Script Files in PamWin-3 for reproducible measurements.
Interfaces and outputs
USB 2.0 / RS-232 for PC connection; fiber-optic and accessory ports.
Software / PC compatibility
PamWin-3 (Heinz Walz) for Windows – quenching analysis, light curves, fast and slow kinetics.
Memory / data storage functions
Data storage on PC with automatic protocol generation in PamWin-3.
Operating conditions
Operating temperature 0…+45 °C; humidity up to 90 % (non-condensing).
Power supply
Powered via AC adapter (100–240 V, 50/60 Hz) or portable UMPC through USB.
Battery life
Up to 8 hours when operated from UMPC or external battery.
Dimensions
23 × 10.5 × 10.5 cm.
Weight
Approx. 1.5 kg (including cable).
Scope of supply
PAM-2500 fluorometer, 2030-B leaf clip, KS-2500 cuvette with stirrer, optional UMPC, PamWin-3 software, cables, manual.
Certificates and compliance with standards
CE, ISO 9001, GLP compliant; manufactured by Heinz Walz GmbH.
Country of origin
Germany
Storage conditions
Store dry at +5…+40 °C, protect from dust and moisture.