Cart 0
Compare 0 Wishlist 0
Menu
Our address: 100011, Tashkent city, Shaykhantakhur district, A. Navoi street, 16a
100011, Tashkent city, Shaykhantakhur district, A. Navoi street, 16a
Mon-Fri: from 9 am to 6 pm
Sat: from 10 am to 5 pm
Sun: from 11 am to 4 pm
0 UZS

Fluke 8558A – 8.5-Digit Precision Multimeter

Fluke 8558A – 8.5-Digit Precision Multimeter
Brand: Fluke
Product Code: F8558
Reviews: (0)
Pre-Order
0 UZS
Buy in one click
Specifications: (see all)
Measured / controlled parameters
High-precision measurement of DC and AC voltage, DC and AC current, resistance, frequency, temperature, capacitance, and high-speed signal digitizing (Digitize V/I) modes.
Measurement / testing range
DC Voltage: 100 mV – 1000 V AC Voltage: 10 mV – 1000 V (1 Hz – 10 MHz) DC Current: 10 µA – 2 A AC Current: 10 µA – 2 A (1 Hz – 100 kHz) Resistance: 1 Ω – 10 GΩ Frequency: up to 100 MHz Capacitance: 1 nF – 100 mF Temperature: supports PRTs and thermocouples
Measurement accuracy / precision
DCV: ±(4.0 µV/V reading + 0.06 µV/V range) ACV: ±(80 µV/V + 10 µV/V) Resistance: ±(10 µΩ/Ω + 0.6 µΩ/Ω) DCI: ±(10 µA/A + 5 µA/A) ACI: ±(300 µA/A + 100 µA/A) Frequency: ±0.5 µHz/Hz
Maximum load / force
Frequency / test speed range
1 Hz – 10 MHz (AC Voltage), 1 Hz – 100 kHz (AC Current), up to 100 MHz (frequency).
Delivery Information DEPENDING ON THE SIZE AND QUANTITY OF THE PRODUCT Payment Pay quickly and conveniently

The Fluke 8558A is a state-of-the-art 8.5-digit precision bench multimeter engineered to deliver unmatched accuracy and reliability for the most demanding measurement applications. Designed for use in calibration laboratories, research facilities, and industrial metrology centers, it provides exceptional performance in measuring DC/AC voltage, current, and resistance with minimal uncertainty.
With a maximum reading rate of up to 100,000 readings per second, the Fluke 8558A is perfect for testing dynamic signals and high-speed measurement scenarios. Its robust measurement stability ensures consistent results over extended periods, making it a trusted reference instrument in the industry.
Equipped with USB, Ethernet, and GPIB interfaces, the 8558A seamlessly integrates into automated test systems and supports Fluke Calibration software, enabling complex measurement automation and data logging. Its bright, easy-to-read display and intuitive user interface make operation straightforward and efficient.
Compliant with international metrology standards, the Fluke 8558A features advanced self-diagnostic and calibration capabilities, ensuring long-term operational reliability and accuracy throughout its service life.

Tags: Calibration and metrology

Calibration and metrology
Measured / controlled parameters
High-precision measurement of DC and AC voltage, DC and AC current, resistance, frequency, temperature, capacitance, and high-speed signal digitizing (Digitize V/I) modes.
Measurement / testing range
DC Voltage: 100 mV – 1000 V AC Voltage: 10 mV – 1000 V (1 Hz – 10 MHz) DC Current: 10 µA – 2 A AC Current: 10 µA – 2 A (1 Hz – 100 kHz) Resistance: 1 Ω – 10 GΩ Frequency: up to 100 MHz Capacitance: 1 nF – 100 mF Temperature: supports PRTs and thermocouples
Measurement accuracy / precision
DCV: ±(4.0 µV/V reading + 0.06 µV/V range) ACV: ±(80 µV/V + 10 µV/V) Resistance: ±(10 µΩ/Ω + 0.6 µΩ/Ω) DCI: ±(10 µA/A + 5 µA/A) ACI: ±(300 µA/A + 100 µA/A) Frequency: ±0.5 µHz/Hz
Maximum load / force
Frequency / test speed range
1 Hz – 10 MHz (AC Voltage), 1 Hz – 100 kHz (AC Current), up to 100 MHz (frequency).
Test temperature range
Operating temperature: +5 °C – +40 °C.
Test humidity range
<90% at +5 °C – +40 °C; <95% at 0 °C – +70 °C (non-condensing).
Test method / operating principle
Precision 8.5-digit digital multimeter using integrating ADC measurement method, signal digitizing function, and built-in filters.
Control type
Digital, soft-key, and computer control (via GPIB, USB, Ethernet interfaces).
Availability of automatic mode / programmable cycles
Yes, supports automated sequences via SCPI commands.
Number and type of sensors
Built-in voltage, current, resistance measurement circuits; supports external temperature sensors (PRT, thermocouples).
Deformation rate / heating-cooling rate
Working chamber / test table material
Working chamber volume / test table size
Approx. 300 x 300 mm (platform).
Cooling / ventilation system
Built-in passive and active cooling for operational stability.
Heating system
Lubrication / medium supply system
Test drive type
Interfaces and outputs:
USB, Ethernet, GPIB, external trigger ports, USB flash drive port.
Software / PC compatibility
Compatible with MET/CAL™, emulation of Fluke 8508A and Keysight 3458A.
Memory / data storage availability
Up to 15 million readings, CSV export.
Display / indication type
Color graphical display with trends, histograms, and FFT modes.
Calibration / self-diagnostics capability
Yes, supports internal and external calibration, self-test.
Power supply
100–120 / 200–240 V AC, 50/60 Hz.
Protection class / operational safety
CAT I 1000 V, CAT II 300 V, IEC61010 compliant.
Dimensions
431 × 88 × 475 mm (without handles), 440 × 88 × 510 mm (with handles).
Weight
9.8 kg.
Scope of supply / delivery set
Fluke 8558A, power cord, manual, measurement leads, software.
Country of origin
China
Reviews
0/ 5
average product rating
0
0
0
0
0
There are no reviews for this product. Be the first to leave your review.

No questions about this product, be the first and ask your question.